Disaggregated Prefill#

Overview#

Disaggregated prefill (P/D) runs prefill and decode on separate vLLM instances: a prefill instance computes the prompt’s KV, hands it to a decode instance over NIXL, and the decoder generates tokens without recomputing the prompt. Prefill- and decode-heavy work then scale independently.

LMCache MP adds cross-request KV reuse on top. Each vLLM instance also offloads its KV to a co-located LMCache server, so a recurring prefix — on a later request, or after eviction from GPU HBM — is loaded from LMCache instead of recomputed. KV-source order on the prefill path: local GPU cache → LMCache → recompute.

Both are composed with vLLM’s MultiConnector, which runs two connectors per instance:

  • NixlConnector — the prefill→decode KV handoff for the current request, over NIXL (UCX / RDMA).

  • LMCacheMPConnector — offload/load to the instance’s LMCache server for cross-request reuse.

A vLLM router in P/D mode sends each request to a prefill then a decode instance and threads the NIXL handshake between them.

How it works#

A minimal deployment is five processes:

  • Prefill vLLM (producer) — MultiConnector[NixlConnector (kv_producer), LMCacheMPConnector]; computes prompt KV, stores it to its LMCache server, and exposes it for the decoder to pull over NIXL.

  • Decode vLLM (consumer) — MultiConnector[NixlConnector (kv_consumer), LMCacheMPConnector]; pulls prompt KV from the producer and generates output.

  • Two LMCache servers — one lmcache server per vLLM instance (they must not share one).

  • Router — vllm-router --vllm-pd-disaggregation routes prefill then decode.

To share reuse across the prefill and decode pools too, layer P2P KV cache sharing on top (give both servers a coordinator and --p2p-advertise-url).

Requirements#

Important

vllm-project/vllm#46865 (the MultiConnector real-blocks fix) unblocks LMCache offload under MultiConnector. Without it, offload silently never triggers.

  • NIXL available in the vLLM environment (lmcache[nixl] extra, which pulls nixl>=1.3.0).

Configuration#

Each vLLM instance takes a --kv-transfer-config selecting MultiConnector with two sub-connectors:

Key

Description

kv_connector = MultiConnector

Runs the kv_connector_extra_config.connectors side by side.

kv_role

kv_producer (prefill) or kv_consumer (decode), on both the top-level MultiConnector and the nested NixlConnector.

NixlConnector

The prefill→decode handoff. Set kv_load_failure_policy = fail so a failed transfer surfaces instead of silently recomputing.

LMCacheMPConnector

Offload/load to the local LMCache server; use kv_role = kv_both. kv_load_failure_policy is a NixlConnector setting above, not an LMCacheMPConnector one — LMCache’s own L2 adapters (including its own optional Nixl-backed L2 store) do not currently distinguish a load failure from a cache miss, so setting it here would have no effect.

lmcache.mp.host / lmcache.mp.port

Request transport, host, and --port of the instance’s LMCache server (distinct per instance).

The NIXL transfer is tuned via environment variables on the vLLM instances: VLLM_NIXL_SIDE_CHANNEL_HOST (host advertised for the handshake, reachable by the peer), VLLM_NIXL_SIDE_CHANNEL_PORT (must differ between instances on the same host; default 5600), plus UCX_NET_DEVICES=all and NCCL_CUMEM_ENABLE=1. See lmcache server for the full lmcache server flag list.

Running a deployment#

The example below places the prefill pool, the decode pool, and the router on separate hosts. Replace <PREFILL_IP> / <DECODE_IP> with routable addresses and <model> with the model path (identical on both instances).

Step 1 — prefill LMCache server (on the prefill host):

lmcache server \
    --port 6555 --http-port 8090 \
    --l1-size-gb 100 --eviction-policy LRU --chunk-size 256 \
    --instance-id prefiller

Step 2 — prefill vLLM (producer) (on the prefill host):

VLLM_NIXL_SIDE_CHANNEL_HOST=<PREFILL_IP> VLLM_NIXL_SIDE_CHANNEL_PORT=5600 \
UCX_NET_DEVICES=all NCCL_CUMEM_ENABLE=1 \
vllm serve <model> \
    --port 8001 --tensor-parallel-size 1 \
    --kv-transfer-config '{"kv_connector":"MultiConnector","kv_role":"kv_producer","kv_connector_extra_config":{"connectors":[{"kv_connector":"NixlConnector","kv_role":"kv_producer","kv_load_failure_policy":"fail"},{"kv_connector":"LMCacheMPConnector","kv_role":"kv_both","kv_connector_extra_config":{"lmcache.mp.host":"grpc://localhost","lmcache.mp.port":6555}}]}}'

The producer advertises its NIXL side channel on <PREFILL_IP>:5600 and offloads to the LMCache server on port 6555.

Step 3 — decode LMCache server (on the decode host):

lmcache server \
    --port 6556 --http-port 8091 \
    --l1-size-gb 100 --eviction-policy LRU --chunk-size 256 \
    --instance-id decoder

Step 4 — decode vLLM (consumer) (on the decode host):

VLLM_NIXL_SIDE_CHANNEL_HOST=<DECODE_IP> VLLM_NIXL_SIDE_CHANNEL_PORT=5558 \
UCX_NET_DEVICES=all NCCL_CUMEM_ENABLE=1 \
vllm serve <model> \
    --port 8002 --tensor-parallel-size 1 \
    --kv-transfer-config '{"kv_connector":"MultiConnector","kv_role":"kv_consumer","kv_connector_extra_config":{"connectors":[{"kv_connector":"NixlConnector","kv_role":"kv_consumer","kv_load_failure_policy":"fail"},{"kv_connector":"LMCacheMPConnector","kv_role":"kv_both","kv_connector_extra_config":{"lmcache.mp.host":"grpc://localhost","lmcache.mp.port":6556}}]}}'

The consumer offloads to the LMCache server on port 6556; its side-channel port (5558) differs from the producer’s so the two can share a host.

Step 5 — router (on any host that can reach both vLLM instances):

vllm-router \
    --policy round_robin \
    --vllm-pd-disaggregation \
    --prefill http://<PREFILL_IP>:8001 \
    --decode http://<DECODE_IP>:8002 \
    --host 0.0.0.0 --port 30000

Send requests to the router (http://<ROUTER_IP>:30000/v1/...); it handles the prefill→decode split transparently.

Running on a single node (testing & debugging)#

Same five processes over localhost, prefill on GPU 6 and decode on GPU 7. The instances must differ in every shared-host port: the LMCache --port and --http-port, the vLLM --port, and VLLM_NIXL_SIDE_CHANNEL_PORT.

lmcache server --port 6555 --http-port 8090 \
    --l1-size-gb 100 --eviction-policy LRU --chunk-size 256 --instance-id prefiller

CUDA_VISIBLE_DEVICES=6 VLLM_NIXL_SIDE_CHANNEL_HOST=127.0.0.1 VLLM_NIXL_SIDE_CHANNEL_PORT=5600 \
UCX_NET_DEVICES=all NCCL_CUMEM_ENABLE=1 \
vllm serve <model> --port 8001 --enforce-eager --max-model-len 16384 --gpu-memory-utilization 0.4 \
    --kv-transfer-config '{"kv_connector":"MultiConnector","kv_role":"kv_producer","kv_connector_extra_config":{"connectors":[{"kv_connector":"NixlConnector","kv_role":"kv_producer","kv_load_failure_policy":"fail"},{"kv_connector":"LMCacheMPConnector","kv_role":"kv_both","kv_connector_extra_config":{"lmcache.mp.host":"grpc://localhost","lmcache.mp.port":6555}}]}}'

lmcache server --port 6556 --http-port 8091 \
    --l1-size-gb 100 --eviction-policy LRU --chunk-size 256 --instance-id decoder

CUDA_VISIBLE_DEVICES=7 VLLM_NIXL_SIDE_CHANNEL_HOST=127.0.0.1 VLLM_NIXL_SIDE_CHANNEL_PORT=5558 \
UCX_NET_DEVICES=all NCCL_CUMEM_ENABLE=1 \
vllm serve <model> --port 8002 --enforce-eager --max-model-len 16384 --gpu-memory-utilization 0.4 \
    --kv-transfer-config '{"kv_connector":"MultiConnector","kv_role":"kv_consumer","kv_connector_extra_config":{"connectors":[{"kv_connector":"NixlConnector","kv_role":"kv_consumer","kv_load_failure_policy":"fail"},{"kv_connector":"LMCacheMPConnector","kv_role":"kv_both","kv_connector_extra_config":{"lmcache.mp.host":"grpc://localhost","lmcache.mp.port":6556}}]}}'

vllm-router --policy round_robin --vllm-pd-disaggregation \
    --prefill http://localhost:8001 --decode http://localhost:8002 --host 0.0.0.0 --port 30000

Add --enable-tracing --otlp-endpoint http://localhost:4317 to each lmcache server to export traces/metrics to a local OpenTelemetry collector.

Note

On a single host, NIXL over localhost uses loopback/TCP, not RDMA, so latencies are not representative — single-node mode is for functional testing only.

Verifying it is working#

curl -s http://localhost:30000/v1/completions -H "Content-Type: application/json" \
    -d '{"model":"<model>","prompt":"The capital of France is","max_tokens":16}'
  • P/D routing — the response id is stamped with the workers, e.g. cmpl-___prefill_addr_localhost:8001___decode_addr_localhost:8002_....

  • NIXL transfer — the decode vLLM logs KV Transfer metrics: NixlConnector={'Num successful transfers': N, ...}.

  • LMCache offload — storage_manager.l1_manager.total_object_count in curl -s http://localhost:8090/status grows (prompts must be at least --chunk-size tokens to store anything).

  • LMCache hit rate — read vLLM’s “External prefix cache hit rate” log line (the fraction of prefill tokens served from LMCache), not the LMCache server /status. It stays 0 while the working set fits in GPU HBM and rises once reuse spills out of the GPU cache.

Using the Operator#

Warning

The LMCache Kubernetes operator (operator/) is deprecated and no longer maintained. It is expected to be removed from this repository in 2027Q1. Existing release artifacts (e.g. operator-v* install.yaml) will not receive fixes or updates. Do not build new deployments on it.

For Kubernetes deployments, the operator can manage the LMCacheEngine CRs for both the prefiller and decoder roles and automatically inject the MultiConnector config and NIXL env vars into opted-in vLLM pods. See PD Disaggregation for the operator-based setup.

Limitations and tuning#

  • Keep cold KV transfers bounded under high concurrency. vLLM’s native NIXL P/D path is sensitive to many large cold transfers (full-prompt, nothing cached) in flight at once. Keep the decode instance’s GPU KV cache large enough to hold the working set so transfers stay small and cache-served, or reduce concurrency when per-request transfers are large.